The product HRM1 is a general purpose power relay. It is available in 2 Form C contact. It has 4000V dielectric strength between coil and contacts. It has a slim type and the creepage distance is 8mm. HRM1 has passed UL E164730, CSA 1063015 (LR 106040), TUV 50134947-001, CQC 9002035018 safety standards.
| Contact Data | |
| Contact Form | 2C |
| Contact Rating | Resistive: 5A 250VAC/24VDC TV Rating: TV-5 Inductive: 5A 250VAC/24VDC(COSΦ=0.4, L/R=7ms) |
| Max.Switching Voltage | 250VAC/30VDC |
| Max.Switching Current | 5A |
| Max.Switching Power | 1,250VA,150W |
| Min.Switching Load | 5VDC,100mA |
| Coil Data | |
| Coil Voltage | 12VDC |
| General Data | ||
| Dielectric Strength | Open Contacts | 1,000VAC,1min |
| Coil and Contacts | 4,000VAC,1min | |
| Electrical Life(ops.) | 100,000 20,000(COSΦ=0.4, L/R=7ms) |
|
| Operating Temperature | -30~+55℃(720mW) -30~+70℃(540mW) |
|
| Terminal Type | PCB | |