TUBE, LINLAI, 2A3-N, PAIR MATCHED
Description
2A3 is direct-heated cathode middle- power double triode, and it is used as class A1, AB1 amplification.
Features of the 2A3
Ultra purity Permalloy with carbon coating plate – by nature this plate material has superior electron emission to create strong current, and tube life is longer
No-Contact design between filament structure and the glass enclosure to minimize external vibration and resonance
4 metal pole holding the filament structure – very sturdy for survive shipping and handling
Dome shaped glass enclosure – not supersized so it will fit in all current 2A3 tube space
Ceramic base with metal sleeve cover – leaves no finger print residual and never rust
Suggested burn-in time: 100 hrs
Specifications:
Heater
Uf ………………………… 2.5 V
If………………………… 2.5 A
Maximum Rating
Ua…………………………300 V
Pa…………………………15 W
Rg
with cathode bias…………………………0.5 MΩ
with fixed bias…………………………0.05 MΩ
Direct Interelectrode capacitances
input………………………… 7.5 PF
output…………………………16.5 PF
grid to plate…………………………5.5 PF
Static parameter
Ua………………………… 300 V
-Ug………………………… 45 V
Ia………………………… 60 mA
Gm………………………… 5.25 mA/V
ri………………………… 0.8 kΩ
μ………………………… 4.2
Pout…………………………3.5 W
Recommended Operating Conditions (reference value)
Class A1, single tube (fixed bias)
Ua………………… 250 V
-Ug……………………45 V
RL……………………2.5 kΩ
Ia(0)…………………60 mA
Gm……………………5.25 Ma/V
ri……………………0.8 Kω
μ……………………4.2
Pout……………………3.5 W
Dtot……………………5 %
Class AB1, push-full (fixed bias)
Ua……………300 300 V
-Ug……………62 Rk=780Ω V
RL……………3 5 kΩ
üg(pk)………87 110 V
Ia(0)…………80 80 mA
Ia(max.sig)…140 100 mA
Pout……………15 10 W
Dtot……………2.5 5 %