location_on 4131 Fraser St. Vancouver BC Get Directions
phone 604-875-1993 Call us
access_time Hours
Monday - Friday | 9AM - 5:30PM |
Saturday - Sunday & Holidays | Closed | See Holiday Hours |
•Technical data
Current rating range 0.5A
Input voltage rating 125/250VAC; 32VDC
Interrupting Capacity 125/250VAC x 1,000A
Typical life 1,000 operations at 200% overload
Insulation co-ordination Rated impulse withstand voltage 2.5kV
Dielectric Strength > 1,500VAC/min
Insulation Resistance >100MOHM (DC 500V)
Degree of protection Terminal area IP00,operating area IP40
•Mechanical/Environmental Data
Operating Ambient Temperature: -10 to +60℃℃
Termination: 250’’(6.35mm)quick connects or solder terminals
Mounting: Various options. See Ordering Information and drawings
•Typical applications
Transformers, Motors, Battery chargers, Power supplies
appliances, extra low voltage systems, machinery.
•Calibration(at 25℃)
Rated: 0.25~2.5A
100% of Rated Current: Hold , No Trip
•150% of Rated Current: Trip Within 1 Hour.
•200% of Rated Current: 7.5-52 sec Trip
•300% of Rated Current: 2.85-10 sec Trip