Ratings

Degree of protection Closed type (cover)
Terminal structure Plug-in terminal
CoilCoil ratings 220 VAC 50 Hz 4.8 mA
220 VAC 60 Hz 4.2 mA
240 VAC 50 Hz 5.3 mA
240 VAC 60 Hz 4.6 mA
Coil resistance 18790 Ω
Operate voltage (Set voltage) 80 % max.
Release voltage (Reset voltage) 30 % min.
Maximum voltage 110 %
Power consumption Approx. 0.9 to 1.1 VA 60 Hz
ContactContact rated load 10 A (Resistive load)
110 VAC 7.5 A (Inductive load (cosφ = 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))
Max. contact voltage 250 VAC
125 VDC
Max. contact current AC: 10 A
DC: 10 A
Contact form DPDT
Contact method Single
Contact material Ag alloy

Performance

Contact resistance 50 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Reset time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Maximum operating frequency Mechanical: 18000 time/hour
Rated load: 1800 time/hour
Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 2000 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Shock resistance (destruction) 1000 m/s2
Shock resistance (Malfunction) 200 m/s2
Endurance (Mechanical) 50 million operations min. (switching frequency 18,000 operations/h)
Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute)
Ambient temperature (Operating) -25 to 55 ℃ (with no freezing or condensation)
Ambient humidity (Operating) 5 to 85 %
Weight Approx. 40 g
Mounting method Socket
Applicable socket PTF-08-PU/ PTF-08-PU-L/ PTF08A/ PTFZ-08-E/ PT08/ PT08QN/ PT08-0