Continuously adjustable from 0.01 seconds to 9999 minutes.
Enter the settings interface when short press button ‘Pause’ in the OP / CL parameter modification interface(Flashing) to select timing range.
Pay attention to the position where the decimal point moves when the button is pressed.
Display ‘XXXX’. No decimal point, the timing range is 1 second ~ 9999 seconds.
Display ‘XXX.X’. The decimal point is the penultimate, timing range is 0.1 second to 999.9 seconds.
Display ‘XX.XX’. The decimal point is the third last, timing range is 0.01 second to 99.99 seconds.
Display ‘X.X.X.X’. The decimal point is fully lit, timing range is 1 minute to 9999 minutes.
For example, if you want to set the OP to 3.2 seconds, move the decimal point to the penultimate position, LCD will display ‘003.2’.
OP: Turn On time;
CL: Turn OFF time;
LOP: Number of cycles.Range is 1-9999tims.’----’ means unlimited loop.
Long press:keep press button for more than 3second.
1 Enter set parameter menu by long press button 'SET'.
2 Work mode will flash at first set the working mode.Short press the UP/DOWN button to set the working mode.
3 Short press the SET button to select the working mode and enter the system parameter settings.
4 In the system parameter setting interface, short press the ‘SET’ button to switch the system parameters to be modified, short/long press the UP/DOWN button to modify value;
Note:Short press ‘SET ’ is invalid at mode P0,P1,P2,P3,P7,P8.
5 Enter setting interface when short press button ‘Pause’ in the OP/CL parameter modification interface(Flashing) to select timing range (1s/0.1s/0.01s/1min).
6 Save the parameter settings and exit the settings interface when long press ‘SET’ button after all the parameters are set.
UART Communication and Parameter Settings
The system supports UART data upload and parameter setting functions (TTL level);
UART: 9600, 8, 1
NO. Command Function
1 Read Read the parameter setting
2 OP:XXXX Set the minimum delay time for turn ON : 1s
3 OP:XXX.X Set the minimum delay time for turn ON : 0.1s
4 OP:XX.XX Set the minimum delay time for turn ON : 0.01s
5 OP:X.X.X.X Set the minimum delay time for turn ON : 1min
6 CL:XXXX Set the minimum delay time for turn OFF : 1s
7 CL:XXX.X Set the minimum delay time for turn OFF : 0.1s
8 CL:XX.XX Set the minimum delay time for turn OFF : 0.01s
9 CL:X.X.X.X Set the minimum delay time for turn OFF : 1min
10 LP:XXXX Number of cycles:1-9999
11 Start Trigger/Start(Just for P0~P7)
12 Stop Pause(Just for P0~P7)
13 PX Set mode P0~P9
Note
This is a relay output and cannot be used as a power module.
It cannot output voltage. The load needs to be connected to a separate power supply.