All pictures are for illustrative purposes only.
Store address and hours
location_on 4131 Fraser St. Vancouver BC Get Directions
phone 604-875-1993 Call us
access_time Hours
Monday - Friday | 9AM - 5:30PM |
Saturday - Sunday & Holidays | Closed | See Holiday Hours |
Closed
• Opens Fri at 9AM
close
Menu
-
close
-
CATEGORIES
-
-
-
-
-
-
-
-
-
-
-
-
-
Featured Item
-
-
-
-
-
-
-
more electrical devices
More electrical devices -
more electrical devices
More electrical devices
-
-
more electrical devices
More electrical devices -
more electrical devices
More electrical devices
-
-
Featured Items
-
more electrical devices
More electrical devices
-
-
-
-
-
-
-
-
Featured Item
-
-
-
-
-
-
-
Featured Items
-
-
-
-
-
-
-
-
Featured Items
-
-
-
Featured Items
-
-
-
-
-
-
-
-
-
-
-
Featured Items
-
-
-
-
-
-
-
-
-
Featured Items
-
-
-
-
-
-
featured
-
-
-
Featured Items
-
-
-
-
-
-
-
Featured Items
-
-
-
-
-
Featured Items
-
-
-
-
Featured Products
-
-
-
More Filaments
More Filaments
-
-
-
-
more electrical devices
More electrical devices
-
-
more electrical devices
More electrical devices
-
-
Electrical Devices
-
-
-
more electrical devices
More electrical devices
-
-
-
-
-
-
-
Featured Products
-
-
-
Featured Products
-
-
-
-
BRANDS
-
-
-
-
Brands/Manufacturers
-
-
Manufacturer 3
-
-
- PROJECTS
-
COMMUNITY
-
- SALE Sale
- GST/HST Break
AC CURRENT DETECTION SENSOR MODULE, 12V RELAY
PID# 18570
15,00 CA$ EACH
Description
Specifications:
Operating voltage: DC12V
Operating current: <20MA
Operating frequency range: 20Hz ~ 400Hz
Output mode: switch signal output
Maximum detection wire diameter: 5.2mm
Mounting hole: hole diameter is 3mm, hole distance is 52.5mm
Operating environment: -40 ℃ ~ +85 ℃
The current detection range :AC0.3A-5A
Board size: 38 * 44mm
The Board Description:
VCC: Operating voltage positive;
GND :Operating voltage negative;
NO: Normally open, the relay pulls before the NO and COM disconnect, short-circuit after the suction;
COM: common, relay common interface;
NC: Normally closed, the relay before the NC and COM short-circuit, pull off after.
Using Instructions:
By setting the potentiometer to set the overcurrent protection point, the clockwise adjustment reduces the detection current.
As bellows:
1. Measured the wire through the current transformer , connect VCC and GND to DC12V power supply;
2. Adjust the potentiometer, when you hear the sound of the relay pull (can be measured with a multimeter COM and NO whether was turned on, if connected to the relay means activated), then reduce or cut off the current flowing that through the tested wire , if the relay release at this time that over-current protection point has been identified (available to multimeter COM and NC measurement whether is connected, if connected to the relay means been released);
3. When reduce or cut off the current flowing through the wire , the relay is not released, will still need to continue to adjust the potentiometer to find the over-current protection point.