12VDC PROGRAMMABLE TIMER 0-999MINS

All pictures are for illustrative purposes only.

PID# 1816

15,00 CA$ EACH
Free shipping: On orders over $120 within BC
Quantité

Request a large quantity quote

Description

Feature:

1. Programmable / LED display, easy to use.

2. Can save your setting, we you power up next time, it will run your previous setting.

3. Wide Time Range

4. Can turn off the LED display and save power.

5. Widely use in Car / Motor Control/ LED lamp/ Valve and industry...

Usage:

When it connect to 12V power supply, the timer will run, when the timer run out, and the relay switch work.

K1 = settings
K2 = add
K3 = minus
K4 = turn on/off digital display

Long press K1 to see which mode it is on: P-xx
press k2, k3 to select your modes, then short press k1 to confirm then the screen prompt user to enter a A time setting (screen at this point is: Axx). Short press K2 or K3 to add and minus time by 1, long press to quickly add and minus time by 10. K4 key sets the decimal points. The time unit is in seconds if it is at 1-99. If there are 3 digits, the time unit is 1-999 minutes. Press K1 to set A time then it will prompt the user to enter B time setting (Bxx). Modify time setting like setting A time setting. Then it will prompt user to set C cycles (Cxx). After getting desire cycles Press K1 again to exit and save all parameters.



Working Modes:
PROGRAM NUMBER  DESCRIPTION SIGNAL A B C
P-11 MOMENTARY ON WHILE HIGH
P-12 TOGGLE TOGGLES ON RISING EDGE
P-13 TIMER TRIGGERS TIMER A ON TIME
P-14 TIMER (RESETTABLE) TRIGGERS TIMER A. RISING EDGE RESETS ON TIME
P-15 TIMER (CUMULATIVE) ADDS "A" TIME TO TIMER ON TIME
P-16 TIMER (W/DISABLE) TRIGGERS TIMER A, HIGH DISABLES ON TIME (HIGH DISABLES)
P-17 TIMER (HIGH RESET) HIGH ON, FALLING EDGE TRIGGERS TIMER A ON TIME
P-18 TIMER (POWER) N/A (POWER ON STARTS TIMER A) ON TIME
P-21 DELAY (RISING EDGE) RISING EDGE TRIGGERS TIMER A DELAY TIME (IGNORE SIGNAL)
P-22 DELAY (HOLD HIGH) TRIGGERS TIMER A, THEN HOLDS ON WHILE HIGH DELAY TIME (LOW DISABLES)
P-23 DELAY (FALLING EDGE) FALLING EDGE TRIGGERS TIMER A DELAY TIME
P-24 DELAY/TIMER (HOLD HIGH /DELAYED RESET) TIMER A WHEN HIGH, THEN TURNS ON. WHEN ON, FALLING EDGE WILL TRIGGER A COUNTDOWN FOR "A" TIME. IF THE SIGNAL IS LOW AT 0 SECONDS, RELAY TURNS OFF. OTHERWISE, IT STAYS ON. DELAY TIME
P-25 TOGGLE (HOLD HIGH) TOGGLE AFTER HOLDING FOR "A" TIME SIGNAL TIME
P-26 TIMER (EDGE TRIGGER) EDGE TRIGGER STARTS TIMER ON TIME
P-27 DELAY (RISING EDGE RESET) RISING EDGE TURNS OFF RELAY AND STARTS TIMER A DELAY TIME (RISING RESETS)
P-28 DELAY (POWER) N/A (POWER STARTS TIMER) DELAY TIME
P-31 ON/OFF LOOP N/A (POWER STARTS TIMER) ON TIME OFF TIME
P-32 ON/OFF LOOP (LEVEL HIGH) LOOP ACTIVE WHILE HIGH ON TIME OFF TIME
P-33 ON/OFF LOOP (TOGGLE) SIGNAL TOGGLES LOOP ON TIME OFF TIME
P-34 DELAY/TIMER (POWER) N/A (POWER STARTS TIMER) DELAY TIME ON TIME
P-35 DELAY/TIMER (HIGH TRIGGER) STARTS TIMER A DELAY TIME ON TIME
P-36 DELAY/TIMER (HOLD HIGH) TIMERS RUN WHILE HIGH. LOW DISABLES DELAY TIME ON TIME
P-37 TIMER/IGNORE STARTS TIMER A ON TIME IGNORE SIGNAL
P-38 ON/OFF/ON STARTS TIMER A ON TIME OFF TIME
P-41 TIMER (FALLING EDGE) HIGH DISABLES RELAY, FALLING EDGE TRIGGER ON TIME
P-42 DELAY/TIMER (FALLING EDGE) FALLING EDGE TRIGGER DELAY TIME ON TIME
P-43 DELAY/TIMER (HOLD LOW) FALLING EDGE TRIGGER. HIGH DISABLES TIMER A ON TIME OFF
P-44 ON/OFF LOOP COUNT TOGGLES TIMERS "C" TIMES ON TIME OFF TIME LOOP COUNT
P-45 ON/OFF LOOP COUNT (HIGH TRIGGER) HIGH TRIGGERS, LOOPS "C" TIMES ON TIME  OFF TIME LOOP COUNT
P-46 COUNTER COUNTS "A"+1 PULSES SIGNAL COUNT
P-44 TIMER (COUNTER) COUNTS "A"+1 PULSES, THEN TRIGGERS TIMER B SIGNAL COUNT ON TIME
P-48 TIMER (TIMED COUNTER) REQUIRES "A"+1 PULSES IN "C" SECONDS TO TRIGGER TIMER B SIGNAL COUNT ON TIME COUNTER TIME

Working mode (32 types):

P-11: Jog mode, with signal pull-in, no signal disconnect.

P-12: Self-locking mode, the state of the relay flips once every time the hornworm is launched.

P-13: After triggering, the relay pulls in and disconnects after the delay time; during the delay period, the electric transmission is invalid.

P-14: After triggering, the relay will be closed and disconnected after the delay time; during the delay period, the hornworm will re-timing.

P-15: After triggering, the relay pulls in and disconnects after a delay of A time; during the delay period, the hornworm sends a cumulative timing.

P-16: After the hornworm is sent out, the relay is closed and disconnected after a delay of A time; during the delay period, the horn is reset (relay is

off).

P-17: After the hornworm is sent, the relay is closed during the signal duration, the input signal disappears, and it is disconnected after a delay of A time;

during the delay period, the relay is triggered again to remain closed, and the timing stops until the last signal disappears.

Disconnect after time A.

P-18: After power on, the relay will be closed immediately, and will be disconnected after a delay of A seconds; until the next power on.

P-21: Give the signal, the relay will be closed after the delay time A.

P-22: Give a continuous signal. After the time is exceeded, the relay will be closed; the signal disappears and the relay will be disconnected.

P-23: When the signal disappears for more than time A, the relay is closed; when there is a signal, the relay is disconnected.

P-24: a continuous signal A exceeds the time relay; signal disappears over time,

relay disconnected.

P-25: a continuous signal, this time elapses, relay; again to continue the signal, timeA

after the exceeds the relay is open

P-26: the signal, the relay pull-A after disconnection time; relay the signal disappears A second pull again after

stopping

P-27: pulse signal (rising or falling) relay is switched off, no pulse signal,delay

the A time relay energized (continuous or continuous high low are considered to No pulse).

P-28: After power on, the relay will be closed after the delay time A until the power is off.

P-31: After power-on, the relay pulls in for time A, disconnects for time B, infinite loop; power off stops.

P-32: There is a continuous signal, the relay is closed for A time, disconnected for B time, infinite loop; the signal disappears, and the

loop is terminated.

P-33: a primary signal, A relay time, OFF time B, the infinite loop; to give a

signal the loop is terminated.

P-34: After power-on, after the delay time A, the relay will be closed, and the relay will be closed after the time B is closed.

P-35: Give a signal, after delaying time A, the relay will be closed, and disconnected after the time B.

P-36: a continuous signal A exceeds the time relay, the disconnection time after the pull B; signal

disappears the timer is cleared, the relay off. P-37: When there is a signal, the relay will be automatically disconnected after the A time is closed, and then the B time will be counted after the disconnection. The A+B

signal trigger is invalid within the time.

P-38: If there is a signal, the relay will be automatically disconnected after the A time is closed. After the disconnection, the B time will be counted, and then

the A time will be automatically disconnected.

P-41: No action when there is a signal; trigger when the signal disappears; the relay is pulled and disconnected after the delay time A.

P-42: The signal disappears, the relay is closed after the delay time A; the relay is disconnected after the delay time B.

P-43: The signal disappears, and the relay is closed after the disappearance exceeds the time; the relay is disconnected after a delay of B time.

P-44: After power on, the relay will pull in for time A and disconnect for time B; the relay will be disconnected and stopped after the cycle.

P-45: No action after power-on; after the signal is given, the relay pulls in for A time and disconnects for B time;cycle times

after the, the relay is disconnected and stopped; when the signal is given, it is executed again.

P-46: After giving the signal more than 4 times, the relay will be closed; it will remain closed; the power will stop.

P-47: After giving the signal more than A times, the relay will be closed; after the time of B, it will be disconnected.

P-48: In the C time, after giving the signal more than 4 times continuously, the relay will be closed and disconnected after the B time.

Parameter:

1: size: 65mm*34.3mm*17.5mm

2: Relay Capacity: DC 30V 10A AC 220V10A

3: Standby current: 20mA, working current 60mA

4: working voltage: DC12V